Skip to content
|
 | |  |
 | | | Products Factory Automation |
|  | |  | | | | | | | |
| |  |
|  | | | | | |  | |  |  | | Datasheet as PDF in following languages: |
|  | |  | |  |  | | General specifications |  | |
|  | | Functional safety related parameters |  | | |  |  | | Diagnostic Coverage (DC) | 0 % |
|
|
|
|  | | Indicators/operating means |  |  |  | | LED red/green | Operating display / Alignment aid |
|
|
|
|  | | Electrical specifications |  |  |  | | Operating voltage | 10 ... 30 V DC 5 V DC for RS 422 |
|
|  |  | | No-load supply current | max. 55 mA |
|
|
|
|  | | Output |  |  |  | | Output type | push-pull, incremental (RS 422, incremental) |
|
|  |  | | Voltage drop | ≤ 2.5 V (< 2.5 V) |
|
|  |  | | Operating current | max. per channel 30 mA , short-circuit proof (max. per channel 20 mA, conditionally short-circuit proof) |
|
|  |  | | Output frequency | max. 1 MHz |
|
|
|
|  | | Connection |  |  |  | | Cable | ∅4.7 mm, 8 x 0.128 mm2, 2 m |
|
|
|
|  | | Standard conformity |  |  |  | | Protection degree | DIN EN 60529, IP67 , IP68 , IP69K |
|
|  |  | | Climatic testing | DIN EN 60068-2-30 |
|
|  |  | | Emitted interference | EN 61000-6-4:2007 |
|
|  |  | | Interference rejection | EN 61000-6-2:2005 |
|
|  |  | | Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms |
|
|  |  | | Vibration resistance | DIN EN 60068-2-6, 40 g, 10 ... 2000 Hz |
|
|
|
|  | | Ambient conditions |  |  |  | | Operating temperature | -40 ... 100 °C |
|
|  |  | | Storage temperature | -40 ... 100 °C |
|
|
|
|  | | Mechanical specifications |  | | |  |  | | Rotational speed | max. 30000 min -1 |
|
|
|
|
|
|
|
|  |
|  | |
|  | | |
| |
|  | |
|
 |
|
|
|
|
 |