[Change Country]   Australia
You must have cookies enabled to get the best browsing experience on our website.
Learn how to enable cookies.


Datasheet as PDF in following languages:
ENG
FRA
DEU
SPA
Technical Data
General specifications
Pulse count1024 and 2048
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
MTTFd709 a
Mission Time (TM)10 A
PFHd4.35 E-9
PFD3.1 E-5
L10h70 E+9 at 6000 rpm
Diagnostic Coverage (DC)98.9 %
Electrical specifications
Operating voltage5 V DC ± 5 %
No-load supply currentmax. 70 mA
Output
Output typesinus / cosinus
Amplitude1 Vss ± 10 %
Operating currentmax. per channel 10 mA , short-circuit proof, reverse polarity protected
Output frequencymax. 200 kHz (3 dB limit)
Connection
Cable∅6.5 mm, 4 x 2 x 0.14 mm2, 1 m
Standard conformity
Protection degreeDIN EN 60529, IP65
Climatic testingDIN EN 60068-2-78 , no moisture condensation
Emitted interferenceDIN EN 61000-6-4
Interference rejectionDIN EN 61000-6-2 , advanced testing level to IEC 61326-3-1
Shock resistanceDIN EN 60068-2-27, 100 g, 3 ms
Vibration resistanceDIN EN 60068-2-6, 10 g, 55 ... 2000 Hz
Functional safetyIEC 61508:2000
IEC 62061:2005
ISO 13849-1:2006
IEC 61800-5-2:2007
EN 50178:1997
IEC 61326-3-1:2007
Suitable up to SIL 3, PL e depending from configuration, see manual and report
Ambient conditions
Operating temperature-5 ... 80 °C (23 ... 176 °F) , movable cable
-20 ... 80 °C (253 ... 353 K), fixed cable
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Material
Housingaluminium, powder coated
Flangealuminium 3.1645
ShaftStainless steel 1.4305 (303)
Massapprox. 350 g
Rotational speedmax. 12000 min -1
Moment of inertia≤ 25 gcm2
Starting torque≤ 1.5 Ncm
Shaft load
Axial40 N at max. 6000 min-1
10 N at max. 12000 min-1
Radial60 N at max. 6000 min-1
20 N at max. 12000 min-1
View All Products