Serviceline Industrial Sensors
Serviceline Explosion Protection

1-Rod Electrode HR-6**1**

HR-6**1**
  • Sensor for conductive limit value detection
  • Electrodes Ø6 mm (0.24 inch) for length more than 1.5 m (5 foot)
  • 1-rod electrode with electrode socket or terminal box
  • Different rod and thread materials

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  HR-6**1**

General specifications
Typesensor for conductive limit value detection
Equipment architectureA measuring system consists of a rod electrode HR-6**1** with electrode relay KFA6-ER 1.6,
KFD2-ER 1.6, KFD2-ER-Ex1.W.LB or KFA6-ER-Ex1.W.LB.
SeriesHR-6**1**
Input
Measured variablemeasuring voltage directly from the electrode relay
Output
Output signalelectrode relay creates switch signal corresponding to the selected responsiveness.
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006
Conformity
Degree of protectionIEC 60529:2001
Operating conditions
Process conditions
Process temperatureprocess connection 6: <= 150 °C (423 K)
process connection 7: <= 90 °C (363 K)
process connection 8: <= 150 °C (423 K)
Process pressure (static pressure)process connection 6: ≤ 30 bar
process connection 7: ≤ 16 bar
process connection 8: ≤ 6 bar
Mechanical specifications
Degree of protectionIP65 with terminal box
IP52 with plug connector
Connectionterminals in plug connector or in terminal box
plug connector: terminal, max. 1 mm2
terminal box: terminal, max. 2.5 mm2
Materialhousing: stainless steel 1.4571/316Ti, PP or PTFE
process connection: stainless steel 1.4571/316Ti, PP or PTFE
electrode rod: stainless steel 1.4571/316Ti, Hastelloy C, titanium or tantalum
Dimensionshousing: max. Ø43 mm (1.7 inch), height max. 55 mm (2.2 inch)
rod: length L max. 3000 mm (10 foot)
Process connectionthread G1/2 to ISO 228
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027200507
ECLASS 12.027200507
ECLASS 11.027200507
ECLASS 10.0.127200507
ECLASS 9.027200507
ECLASS 8.027200507
ECLASS 5.127200507
ETIM 9.0EC001447
ETIM 8.0EC001447
ETIM 7.0EC001447
ETIM 6.0EC001447
ETIM 5.0EC001447
UNSPSC 12.141111950

Details: HR-6**1**

Function

An electrode relay provides the measuring AC voltage for the electrode.

If the product comes into contact with conductive batch, the measuring circuit between electrode and wall of vessel is closed and the electrode relay is switched.

Approvals: HR-6**1**

Language Selection:
Declaration of ConformityCert No.LanguageFile TypeFile Size
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-3881ALLPDF231 KB
Contamination Declaration
Contamination declaration / Kontaminationserklärung   ALLPDF137 KB